ADVANCED ELECTROACOUSTIC METROLOGY // ROOM EQ WIZARD

Precision Measurement, Time-Domain Diagnostics & DSP Verification in REW

Designed for calibrators, studio acousticians, and loudspeaker engineers already fluent in sweep capture and parametric EQ. This seven-part technical track goes past single-trace SPL curves into FDW validity bounds, minimum/excess phase decomposition, Schroeder/Lundeby decay modeling, modal pole-zero targeting, coherent distortion benching, and headless API workflows.

7 Deep-Dive Modules macOS & Cross-Platform Audio Stack Worked Diagnostics + Quizzes
CURRICULUM MODULES

Seven-Part Technical Track

Each module follows a uniform engineering structure: operational scope, calibrated procedure, trace diagnostics, deeper DSP/acoustic mechanics, a worked rig example, and a verification quiz.

MODULE 01 Not started

I/O Architecture, macOS Java Audio & Calibration Metrology

Locking interface clock/bit-depth in Audio MIDI Setup, resolving macOS TCC microphone blocks, loopback soundcard calibration vs. USB mic sensitivity parsing, FS sine Vrms scaling, and acoustic vs. wired timing reference integrity.

  • Java CoreAudio
  • tccutil
  • Loopback Cal
  • Sens Factor
  • Headroom
MODULE 02 Not started

Log-Sweep Deconvolution, Impulse Response & FDW Windowing

Transfer function/IR duality, negative-time harmonic separation, asymmetric left/right Hann & Tukey windows, 1 / T_window low-frequency resolution limits, cycle/octave FDW isolation, and ETC reflection path-length mapping.

  • IR Windows
  • FDW
  • ETC
  • Step Response
  • 96 PPO
MODULE 03 Not started

Minimum/Excess Phase, Group Delay & Multi-Way Alignment

Decomposing room responses into invertible minimum-phase and non-minimum-phase excess components, IR delay estimation, phase-slope vs. 1/3-octave impulse alignment, Trace Arithmetic regularization, and RMS vs. vector spatial averaging.

  • Excess GD
  • Alignment Tool
  • Trace Arithmetic
  • Vector Avg
  • IACC
MODULE 04 Not started

Room Acoustics, Schroeder Decay & Time-Frequency Analysis

Schroeder backward integration with Lundeby noise-floor compensation, why Topt outperforms T20/T30 in small rooms, C50/C80/D50 clarity, CSD vs. Burst Decay period-axis Q evaluation, Airy/Morlet CWT spectrograms, and T60M decay models.

  • RT60 / Topt
  • Filtered IR
  • CSD & Burst
  • Airy / Morlet CWT
  • RT60 Decay
MODULE 05 Not started

Modal Pole-Zero Analysis, Target Curves & DSP Filter Architecture

Matching modal filters to measured T60 via Pole-Zero plots, configuring bass-managed targets and house curves without headroom collapse, navigating Q/bandwidth conventions across DSP equalisers, and auditing predicted impulse and waterfall outputs.

  • Modal Analysis
  • Pole-Zero
  • House Curves
  • Biquads
  • Predicted IR
MODULE 06 Not started

RTA Spectral Analysis, Periodic Noise & Stepped-Sine Distortion

Zero-leakage live RTA with clock-matched periodic pink noise and rectangular windows, coherent averaging for low-level harmonics, sweep vs. Stepped Sine noise-floor behavior, THD+N/IMD/ENOB/CEA-2010 metrology, and NC/PNC noise-curve verification.

  • Periodic Noise
  • Stepped Sine
  • Coherent Avg
  • CEA-2010
  • ENOB / IMD
MODULE 07 Not started

Impedance Metrology, Thiele-Small Modeling & REST API Automation

Dual-channel sense-resistor rig calibration (open/short/reference), EPDR load severity analysis, sealed-box vs. dual added-mass Thiele-Small extraction, Room Simulator modal approximations, and scripted measurement via REW's localhost REST API.

  • Impedance Cal
  • EPDR
  • Dual Added Mass
  • Room Sim
  • REST API :4735
DIAGNOSTIC QUICK REFERENCE

Measurement Objective → REW View & Validity Gate

Hover or focus highlighted technical terms for inline definitions. Every view in REW carries strict mathematical boundaries that invalidate careless interpretation.

Diagnostic Objective Primary REW View / Tool Critical Configuration Primary Validity Gate / Failure Mode
Direct-sound speaker voicing SPL & Phase + IR Windows Tight right window before 1st reflection, or FDW LF invalid below approx. 1 / window_duration (e.g., 10 ms → ~100 Hz); dashed trace if extended
Subwoofer / main phase integration Alignment Tool + Group Delay Wired loopback or acoustic timing ref; cursor at XO Sub IR peak is broad; anchor t=0 to IR start or cross-correlate 1/3-oct filtered IRs
EQ invertibility check Group Delay (Excess GD) Generate Minimum Phase; remove propagation delay first Flat excess group delay = minimum phase (EQ-able); sharp spikes = non-minimum-phase cancellation
Small-room decay & bass trapping RT60 Decay + Spectrogram Long sweep + adequate IR truncation; Airy/Morlet CWT or CSD Diffuse-field RT60 invalid below Schroeder/few hundred Hz; use Topt and T60M modal decay
Ultra-low electronic distortion RTA → Stepped Sine Dither enabled, coherent averaging, calibrated Vrms Log sweeps suffer rising harmonic noise floor with frequency; stepped sine isolates true ENOB & THD+N
Amplifier load & driver TS extraction Impedance + TS Parameters Non-inductive Rsense; open/short/ref cal; dual added mass Swapped input channels inflate Z by ~R_sense and invert phase by ~180°; monitor EPDR

Audio Stack & Feature Parity

  • Java CoreAudio Only: macOS (10.15+) ships with a private Java runtime and exposes Java drivers exclusively. ASIO and WASAPI exclusive (EXCL:) are Windows-only.
  • Independent I/O Clocks: Java drivers permit separate input and output devices, but clock drift prohibits multi-sweep averaging when clocks are not synced (including USB measurement mics).
  • Sample Rate & Gain: REW V5.30+ exposes up to 1536 kHz (hardware-dependent), but both rate and 24-bit/32-bit format must be pre-set in Audio MIDI Setup. REW's internal volume sliders are disabled on macOS.
  • Legacy Comms Limits: MIDI port selection is disabled by default on macOS (JRE crash risk; override in Preferences → Comms). RS232 and TAG McLaren serial control are Windows 32-bit only.

Operational Paths & CLI Invocations

Reset macOS TCC Microphone Grant (run before launching REW)
tccutil reset Microphone
Launch REW with Localhost REST API Server (default :4735)
open -a REW.app --args -api -port 4735
  • Preferences Plist: ~/Library/Preferences/com.apple.java.util.prefs.plist
  • Logs & Auto-Recovery: ~/Library/Logs/REW (temporary captures retained 7 days in /temp)
  • API Scope: Bound strictly to localhost / 127.0.0.1; GET inspection endpoints are open, while automated sweep control requires the Pro upgrade.